- This topic has 3 replies, 3 voices, and was last updated 14 years, 10 months ago by
Anonymous.
Installation Fail: Why Do I See "sputnik" Instead Of "hotspotsystem"?
-
Anonymous November 5, 2011 at 9:11 pm
I have the WRT54GL v1.1, serial CL7C…
Per your instructions on http://www.hotspotsystem.com/en/hotspot/install_guide_dd-wrt.html
Including the Router Setup Command.
Problem 1:
When I get to step 3 (Built-in hotspot setup) the logo HotSpotSystem is NOT shown, but instead “(((Sputnik”.
I installed
http://www.dd-wrt.com/routerdb/de/download/Linksys/WRT54GL/1.0/1.1/dd-wrt.v24_mini_generic.bin/2123
http://www.dd-wrt.com/routerdb/de/download/Linksys/WRT54GL/1.0/1.1/dd-wrt.v24_std_generic.bin/1963
Then thinking the file might be wrong (router says “DD-WRT v24-sp2 (10/10/09) MINI“) I tried
http://www.dd-wrt.com/routerdb/de/download/Linksys/WRT54GL/1.0/1.1/dd-wrt.v24_vpn_generic.bin/1966
I also tried versions Std Generic, Vpn Generic, Xbox Nokaid.
Still, I looked all around but could not find chillispot. And the Services, HotSpot, HotSpotSystem portion was never available.
Problem 2:
Also, why is it that ANY change I made – with either [Save] or [Apply] will not stay (for example SSID). I get moved to page http://192.168.1.1/apply.cgi and nothing actually gets changed. There is no return from the apply.cgi page, I must go back to 192.168.1.1
Still, under Services, HotSpot, I cannot get to HOTSPOTSYSTEM to install operator username & location ID.
Urgent: Customer site is DOWN!
Anonymous November 5, 2011 at 11:53 pmBased on the screenshot you still have the mini version installed. Mini is not a compatible version. You need to have a standard or mega version of dd-wrt installed.
So in case of WRT54GL you can go with:
– Build 13064 Standard Generic and use the setup command method to set it up OR
– Build 14896 Standard Generic and use the built-in Hotspot System part
For problem #2: this can be a browser issue, try it with Internet Explorer.
Anonymous November 6, 2011 at 4:22 pmanother thing with #2 could be restrictive intranet settings. I’ve seen similar before when people have put overly restrictive settings on their local intranet.
as Roland was saying you’ll need at least standard to be able to use the chillispot settings.
Anonymous November 8, 2011 at 2:17 amThanks everybody for telling me that Mini is not sufficient, I know that. The problem is that FireFox will not let me get past the Apply.cgi page therefore updates were not being pushed to the router.
Solution provided by Roland:
Use IE instead of FireFox.
Once I did that everything works just fine, thank you!
And the solution to problem #2 solved #1.
You must be logged in to reply to this topic.